FEATURES:
• Multifunctional input; the number
of channels can be expanded from the
standard 20.
• Isolated input for all channels;
vibration-resistant; outstanding, worry-free
measurement performance
• Direct data capture to
a USB memory stick
• Equipped with a bright, easy-to-read
large-format TFT LCD
• Long-term data capture for nine
hours enabled when the battery is used |
|
 |
|
| GL800
Main Unit Specifications LAN interfaces: |
| Item |
Description |
| Number of analogue input terminal units |
1unit (20 ch) or Extension unit (max. 200 ch)
Maximum 10 units or 200 ch when using with a PC
|
| Sampling interval |
100 ms (10 ch) to 1 h |
| Pulse / Logic input |
Selectable between Pulse and Logic,
Number of channels : 4 |
| Number of alarm out channels |
4 |
| Interface to PC |
Ethernet (10BASE-T / 100BASE-TX)
USB (Compatible with high speed) |
| Data storage device |
Internal flash memory : 12 MB
USB memory : Saving to the USB memory directly |
| Display |
5.7 inch TFT colour LCD |
| Power supply |
AC adapter : 100 to 240V AC, 50/60 Hz
DC input : 8 to 24 V DC
Battery pack : Max. 2 batteries installable, 9 hours
operation (when using under Graphtec specified condition)
|
| Vibration resistance |
Compatible with JIS Vibration testing methods
for automobile Type 1 Class A-equivalent |
 |
 |
| Input
Terminal Unit Specifications |
| Item |
 |
Description |
| Number of input channels |
20 (M3 screw type terminal) |
| Measurement range |
Voltage
Temperature
Humidity |
+/- 20 mV to 50 V, 1-5 V TC : K, J, E, T, R,
S, B, N, W
PT : Pt100, JPt100, Pt1000
0 to 100 % RH (when using optional humidity sensor
is used) |
 |
 |
 |
| Options |
| Item |
Model |
| Extension terminal base kit |
B-537 |
| 20 ch extension terminal set |
B-538 |
| Battery pack |
B-517 |
| Humidity sensor |
B-530 |
| Logic / Alarm cable |
B-513 |
| DC power cable |
B-514 |
 |
 |
 |
Models
& Prices
| Part
Number |
Description |
Price |
Buy
Online |
| GL800 |
Midi Logger |
£2,030 |
|
 |
 |
 |
 |
|
|
 |
|
 |
|
 |
|
 |