Decentralised CANbus Modules Overview





KEY FEATURES:

• Multi-channel, intelligent measurement data digitalization and transfer via CAN-Bus

• Any number of modules can be networked in accordance with CAN-Bus specifications

• Real-time data processing and data reduction via internal DSP

• Up to 1 kHz per channel sampling rate

• High resolution (up to 16 bits)

• Low power consumption (approx. 2.5 W at 12 V) per module

• Wide power supply range (9 - 32 V DC)

• Wide ambient temperature range (- 30 °C - + 65° C)

• Compact size

• Low weight

• Extremely durable housing

• Two-color LED as status indicator
The CAN-Bus is rapidly spreading through the automotive industry and in the world of automation. Thus, it is becoming vitally necessary for modern data acquisition systems to be able to capture and process field bus data in combination with analog data. All imc universal measurement systems can be equipped with a CAN-Bus interface. If only CAN measurement data are to be captured, then the CAN-data collector busDAQ is an affordable option. To digitalize sensors and make them intelligent, or to construct decentralized measurement networks, the CANSAS family of products offers the right capabilities. Of interest for the Avionic field is the implementation of the ARINC-Bus. Solutions for other popular field busses such as the Interbus-S and Profibus are in preparation.

CANSAS measurement module types
UNI-8 8-channel all-purpose amplifier module for voltage, current, thermocouples, PT100, strain gauges and measurement bridges. Sampling rate 1 kHz/channel.
C8 8-channel module for high-precision temperature measurement with thermocouple, PT100 or voltage measurement.
BRIDGE2 2-channel measurement bridge module for quarter-, half-, or full bridges, and strain gauges.
SC-16 16-channel module for your choice of voltage, current, DIN thermocouple or PT100 measurement; max sampling rate: 500 Hz/channel.
SC-18 8-channel module for your choice of isolated voltage, current, DIN thermocouple or PT100 measurement; max sampling rate. 1000 Hz/channel.
INC-4 4-channel module for connection of incremental encoders with 2 tracks each. For displacement, angle, events, time, frequency, velocity, RPM.
PWM8 8-channel Pulse Width Modulation output module. PWM-frequency 30 Hz – 10 kHz.
P8, P8-IP65 8-channel module for high-precision pressure measurement. Built-in barometer. Measurement modes: relative/absolute pressure.
DAC8 8-channel analog output module for voltage and current sources (±10 V, 0 ... 20 mA)
DO8R/DO16R 8- or 16-channel digital output module with relays.
DO16 16-channel digital output module with 16 open collector outputs.
DI16 16-channel digital input module with TTL or 24 V range.


CANSAS (Standard Size) - Short housing model

Extruded aluminum housing without ventilator fan, dimensions: 111x98x35 mm (W x D x H)

Models & Part Numbers:

Standard measurement modules:
CANSAS-C8 1050107 CAN/C8
CANSAS-Bridge2 1050006
CAN/BRIDGE2
CANSAS-SC16 1050126
CAN/SC16

Measurement modules with isolated inputs:
CANSAS-SCI8
1050128
CAN/SCI8
CANSAS-SCI16
1050127
CAN/SCI16

Binary and incremental measurement modules
CANSAS-INC4
1050008
CAN/INC4
CANSAS-DI16
1050010
CAN/DI16
CANSAS-DO16
1050012
CAN/DO16
CANSAS-DO8R
1050014
CAN/DO8R

Output modules
CANSAS-DAC8
1050016
CAN/DAC8
CANSAS-PWM8
1050121
CAN/PWM8
GPS-signal receiver
1050067
CAN/GSP-Signal

Mounting kit
DIN Rail Mounting Set

1050078

CANCAN/TH-RAIL
DAC8


CANSAS (Type "L") - Long housing model

Extruded aluminum housing without ventilator fan, dimensions: 111x145x75 mm (W x D x H)

Models & Part Numbers:

Standard measurement modules:
CANSAS-L-UNI8-DSUB
1050115
CAN/UNI8-DSUB
CANSAS-L-UNI8-DSUB-350 Ohm
  CAN/UNI8-DSUB-350
CANSAS-L-UNI8-Litton Veam
1050051
CAN/L-UNI8
CANSAS-L-UNI8-Litton Veam-350 Ohm
  CAN/L-UNI8-350
CANSAS-L-DCB8
1050222
CAN/L-DCB8
CANSAS-L-DCB8 350 Ohm
  CAN/L-DCB8-350
CANSAS-L-C8
1050131
CAN/L-C8
CANSAS-L-C8-SUPPLY
1050134
CAN/L-C8-SUPPLY
CANSAS-L-C8 2T
1050130
CAN/L-C8-2T
CANSAS-L-C8 BNC
1050129
CAN/L-C8-BNC
CANSAS-L-SC16
1050148
CAN/L- SC16
CANSAS-L-SC16 Supply
1050214
CAN/L- SC16 Supply
CANSAS-L-SC16 2T
1050220
CAN/L- SC16-2T

Measurement modules with isolated inputs:
CANSAS-L-CI-8


CAN/L-CI8
CANSAS-L-CI-8-Supply


CAN/L-CI8 Supply
CANSAS-L-SCI8
1050150
CAN/L- SCI8
CANSAS-L-SCI8 Supply
1050210
CAN/L- SCI8 Supply
CANSAS-L-SCI8 2T
1050167
CAN/L- SCI8-2T
CANSAS-L-SCI8 BNC
  CAN/L- SCI8-BNC
CANSAS-L-SCI16
1050124
CAN/L- SCI16
CANSAS-L-SCI16-Supply
1050184
CAN/L- SCI16-Supply
CANSAS-L-SCI16 BNC
1050187
CAN/L- SCI16-2T

Binary and incremental measurement modules:
CANSAS-L-INC4
1050056
CAN/L-INC4
CANSAS-L-DI16
1050058
CAN/L-DI16
CANSAS-L-DO16R
1050057
CAN/L-DO16R

Output modules:
CANSAS-L-DAC8
1050055
CAN/L-DAC8

Mounting kit:
19” CANSAS-L-Rack Mounting Kit
1050141
CAN/19BGT-D
DIN Rail Mounting Set
1050078
CAN/TH-RAIL


CANSAS (Type "K-Line") - Cassette Housing Model

Cassette without ventilator fan, 3 U/ 8..24 HP, weight: approx. 900 g, for mounting in the 19"-subrack. CAN-bus and power supply are connected to the module via the 19" sub rack. Connector for CANSAS POWER-socket not included.

Models & Part Numbers:

Standard measurement modules:
CANSAS-K-UNI8-DSUB
1050116
CAN/K-UNI8-DSUB
CANSAS-K-UNI8-DSUB 350 Ohm
  CAN/K-UNI8-DSUB-350
CANSAS-K-UNI8-Litton Veam
1050070
CAN/K-UNI8
CANSAS-K-UNI8-Litton Veam-350 Ohm
  CAN/K-UNI8-350
CANSAS-K-DCB8 DSUB
  CAN/K-DCB8
CANSAS-K-DCB8 350 Ohm DSUB
  CAN/K-DCB8-350
CANSAS-K-C8
1050112
CAN/K-C8
CANSAS-K-C8-SUPPLY
1050135
CAN/K-C8-SUPPLY
CANSAS-K-C8-BNC
1050113
CAN/K-C8-BNC
CANSAS-K-C8-2T
1050114
CAN/K-C8-2T
CANSAS-K-Bridge2
1050088
CAN/K-BRIDGE2
CANSAS-K-SC16
1050123
CAN/K- SC16
CANSAS-K-SC16 Supply
  CAN/K- SC16-Supply
CANSAS-K-SC16 2T
  CAN/K- SC16-2T

Measurement modules with isolated inputs:
CANSAS-K-CI-8

CAN/K-CI8
CANSAS-K-CI-8-Supply
  CAN/K-CI8 Supply
CANSAS-K-SCI8
1050125
CAN/K- SCI8
CANSAS-K-SCI8 Supply
  CAN/K- SCI8-Supply
CANSAS-K-SCI8 2T
  CAN/K- SCI8-2T
CANSAS-K-SCI8 BNC
  CAN/K- SCI8-BNC
CANSAS-K-SCI16
1050124
CAN/K- SCI16
CANSAS-K-SCI16-Supply
  CAN/K- SCI16-Supply
CANSAS-K-SCI16 2T
  CAN/K- SCI16-2T

Binary and incremental measurement modules:
CANSAS-K-INC4
1050092
CAN/K-INC4
CANSAS-K-DI16
1050076
CAN/K-DI16
CANSAS-K-DO8R
  CAN/K-DO8R
CANSAS-K-DO16
1050077
CAN/K-DO16
CANSAS-K-DO16R
1050093
CAN/K-DO16R

Output modules:
CANSAS-K-DAC8-BNC
1050075
CAN/K-DAC8
CANSAS-K-PWM8
1050085
CAN/K-PWM8
     

Mounting kit:
19” CANSAS-K-Rack Mounting Kit
1050069
CAN/19BGT