| Decentralised
CANbus Modules Overview |
|
 |
 |
KEY
FEATURES:
• Multi-channel, intelligent measurement data digitalization and
transfer via CAN-Bus
•
Any number of modules can be networked in accordance with CAN-Bus specifications
•
Real-time data processing and data reduction via internal DSP
• Up to 1 kHz per channel sampling rate
• High resolution (up to 16 bits)
• Low power consumption (approx. 2.5 W at 12 V) per module
• Wide power supply range (9 - 32 V DC)
•
Wide ambient temperature range (- 30 °C - + 65° C)
• Compact size
• Low weight
• Extremely durable housing
• Two-color LED as status indicator |
|
 |
|
The CAN-Bus is rapidly spreading through the automotive industry
and in the world of automation. Thus, it is becoming vitally necessary
for modern data acquisition systems to be able to capture and process
field bus data in combination with analog data. All imc universal
measurement systems can be equipped with a CAN-Bus interface. If
only CAN measurement data are to be captured, then the CAN-data collector
busDAQ is an affordable option. To digitalize sensors and make them
intelligent, or to construct decentralized measurement networks,
the CANSAS family of products offers the right capabilities. Of interest
for the Avionic field is the implementation of the ARINC-Bus. Solutions
for other popular field busses such as the Interbus-S and Profibus
are in preparation.
 |
CANSAS
measurement module types
 |
 |
| UNI-8 |
8-channel
all-purpose
amplifier module
for voltage,
current, thermocouples,
PT100, strain
gauges and
measurement
bridges. Sampling
rate 1 kHz/channel. |
| C8 |
8-channel
module for
high-precision
temperature
measurement
with thermocouple,
PT100 or voltage
measurement. |
| BRIDGE2 |
2-channel
measurement
bridge module
for quarter-,
half-, or full
bridges, and
strain gauges. |
| SC-16 |
16-channel
module for
your choice
of voltage,
current, DIN
thermocouple
or PT100 measurement;
max sampling
rate: 500 Hz/channel. |
| SC-18 |
8-channel
module for
your choice
of isolated
voltage, current,
DIN thermocouple
or PT100 measurement;
max sampling
rate. 1000
Hz/channel. |
| INC-4 |
4-channel
module for
connection
of incremental
encoders with
2 tracks each.
For displacement,
angle, events,
time, frequency,
velocity, RPM. |
| PWM8 |
8-channel
Pulse Width
Modulation
output module.
PWM-frequency
30 Hz – 10
kHz. |
| P8, P8-IP65 |
8-channel
module for
high-precision
pressure measurement.
Built-in barometer.
Measurement
modes: relative/absolute
pressure. |
| DAC8 |
8-channel
analog output
module for
voltage and
current sources
(±10
V, 0 ... 20
mA) |
| DO8R/DO16R |
8- or 16-channel
digital output
module with
relays. |
| DO16 |
16-channel
digital output
module with
16 open collector
outputs. |
| DI16 |
16-channel
digital input
module with
TTL or 24 V
range. |
|
|
 |
| CANSAS (Standard Size)
- Short housing model |
Extruded aluminum housing without ventilator fan, dimensions:
111x98x35 mm (W x D x H)
 |
Models & Part
Numbers:
Standard measurement modules:
 |
 |
 |
| CANSAS-C8 |
1050107 |
CAN/C8 |
| CANSAS-Bridge2 |
1050006
|
CAN/BRIDGE2 |
| CANSAS-SC16 |
1050126
|
CAN/SC16 |
Measurement modules with isolated
inputs:
 |
 |
 |
CANSAS-SCI8
|
1050128
|
CAN/SCI8 |
CANSAS-SCI16
|
1050127
|
CAN/SCI16 |
Binary and incremental measurement
modules
 |
 |
 |
CANSAS-INC4
|
1050008
|
CAN/INC4 |
CANSAS-DI16
|
1050010
|
CAN/DI16 |
CANSAS-DO16
|
1050012
|
CAN/DO16 |
CANSAS-DO8R
|
1050014
|
CAN/DO8R |
Output modules
 |
 |
 |
CANSAS-DAC8
|
1050016
|
CAN/DAC8 |
CANSAS-PWM8
|
1050121
|
CAN/PWM8 |
GPS-signal receiver
|
1050067
|
CAN/GSP-Signal |
Mounting kit
 |
 |
 |
DIN Rail Mounting Set
|
1050078
|
CANCAN/TH-RAIL
DAC8 |
|
|
 |
| CANSAS (Type "L")
- Long housing model |
Extruded aluminum housing without ventilator fan, dimensions: 111x145x75 mm (W
x D x H)
 |
Models & Part
Numbers:
Standard measurement
modules:
 |
 |
 |
CANSAS-L-UNI8-DSUB
|
1050115
|
CAN/UNI8-DSUB |
CANSAS-L-UNI8-DSUB-350
Ohm
|
|
CAN/UNI8-DSUB-350 |
CANSAS-L-UNI8-Litton
Veam
|
1050051
|
CAN/L-UNI8 |
CANSAS-L-UNI8-Litton
Veam-350 Ohm
|
|
CAN/L-UNI8-350 |
CANSAS-L-DCB8
|
1050222
|
CAN/L-DCB8 |
CANSAS-L-DCB8 350 Ohm
|
|
CAN/L-DCB8-350 |
CANSAS-L-C8
|
1050131
|
CAN/L-C8 |
CANSAS-L-C8-SUPPLY
|
1050134
|
CAN/L-C8-SUPPLY |
CANSAS-L-C8 2T
|
1050130
|
CAN/L-C8-2T |
CANSAS-L-C8 BNC
|
1050129
|
CAN/L-C8-BNC |
CANSAS-L-SC16
|
1050148
|
CAN/L- SC16 |
CANSAS-L-SC16 Supply
|
1050214
|
CAN/L- SC16 Supply |
CANSAS-L-SC16 2T
|
1050220
|
CAN/L- SC16-2T |
Measurement modules
with isolated inputs:
 |
 |
 |
CANSAS-L-CI-8
|
|
CAN/L-CI8 |
CANSAS-L-CI-8-Supply
|
|
CAN/L-CI8 Supply |
CANSAS-L-SCI8
|
1050150
|
CAN/L- SCI8 |
CANSAS-L-SCI8 Supply
|
1050210
|
CAN/L- SCI8 Supply |
CANSAS-L-SCI8 2T
|
1050167
|
CAN/L- SCI8-2T |
CANSAS-L-SCI8 BNC
|
|
CAN/L- SCI8-BNC |
CANSAS-L-SCI16
|
1050124
|
CAN/L- SCI16 |
CANSAS-L-SCI16-Supply
|
1050184
|
CAN/L- SCI16-Supply |
CANSAS-L-SCI16 BNC
|
1050187
|
CAN/L- SCI16-2T |
Binary and incremental
measurement modules:
 |
 |
 |
CANSAS-L-INC4
|
1050056
|
CAN/L-INC4 |
CANSAS-L-DI16
|
1050058
|
CAN/L-DI16 |
CANSAS-L-DO16R
|
1050057
|
CAN/L-DO16R |
Output modules:
 |
 |
 |
CANSAS-L-DAC8
|
1050055
|
CAN/L-DAC8 |
Mounting kit:
 |
 |
 |
19” CANSAS-L-Rack
Mounting Kit
|
1050141
|
CAN/19BGT-D |
DIN Rail Mounting Set
|
1050078
|
CAN/TH-RAIL |
|
|
 |
| CANSAS (Type "K-Line") -
Cassette Housing Model |
Cassette without ventilator fan, 3 U/ 8..24 HP, weight: approx. 900 g, for mounting
in the 19"-subrack. CAN-bus and power supply are connected to the module
via the 19" sub rack. Connector for CANSAS POWER-socket not included.
 |
Models & Part Numbers:
Standard measurement
modules:
 |
 |
 |
CANSAS-K-UNI8-DSUB
|
1050116
|
CAN/K-UNI8-DSUB |
CANSAS-K-UNI8-DSUB
350 Ohm
|
|
CAN/K-UNI8-DSUB-350 |
CANSAS-K-UNI8-Litton
Veam
|
1050070
|
CAN/K-UNI8 |
CANSAS-K-UNI8-Litton
Veam-350
Ohm
|
|
CAN/K-UNI8-350 |
CANSAS-K-DCB8
DSUB
|
|
CAN/K-DCB8 |
CANSAS-K-DCB8
350 Ohm DSUB
|
|
CAN/K-DCB8-350 |
CANSAS-K-C8
|
1050112
|
CAN/K-C8 |
CANSAS-K-C8-SUPPLY
|
1050135
|
CAN/K-C8-SUPPLY |
CANSAS-K-C8-BNC
|
1050113
|
CAN/K-C8-BNC |
CANSAS-K-C8-2T
|
1050114
|
CAN/K-C8-2T |
CANSAS-K-Bridge2
|
1050088
|
CAN/K-BRIDGE2 |
CANSAS-K-SC16
|
1050123
|
CAN/K-
SC16 |
CANSAS-K-SC16
Supply
|
|
CAN/K-
SC16-Supply |
CANSAS-K-SC16
2T
|
|
CAN/K-
SC16-2T |
Measurement
modules with isolated
inputs:
 |
 |
 |
CANSAS-K-CI-8
|
|
CAN/K-CI8 |
CANSAS-K-CI-8-Supply
|
|
CAN/K-CI8
Supply |
CANSAS-K-SCI8
|
1050125
|
CAN/K-
SCI8 |
CANSAS-K-SCI8
Supply
|
|
CAN/K-
SCI8-Supply |
CANSAS-K-SCI8
2T
|
|
CAN/K-
SCI8-2T |
CANSAS-K-SCI8
BNC
|
|
CAN/K-
SCI8-BNC |
CANSAS-K-SCI16
|
1050124
|
CAN/K-
SCI16 |
CANSAS-K-SCI16-Supply
|
|
CAN/K-
SCI16-Supply |
CANSAS-K-SCI16
2T
|
|
CAN/K-
SCI16-2T |
Binary
and incremental
measurement modules:
 |
 |
 |
CANSAS-K-INC4
|
1050092
|
CAN/K-INC4 |
CANSAS-K-DI16
|
1050076
|
CAN/K-DI16 |
CANSAS-K-DO8R
|
|
CAN/K-DO8R |
CANSAS-K-DO16
|
1050077
|
CAN/K-DO16 |
CANSAS-K-DO16R
|
1050093
|
CAN/K-DO16R |
Output modules:
 |
 |
 |
CANSAS-K-DAC8-BNC
|
1050075
|
CAN/K-DAC8 |
CANSAS-K-PWM8
|
1050085
|
CAN/K-PWM8 |
| |
|
|
Mounting kit:
 |
 |
 |
19” CANSAS-K-Rack
Mounting Kit
|
1050069
|
CAN/19BGT |
|
|
 |
|
 |
|
 |
|
 |